Project Description

  • Lightide-emergency-led-garage-lights-vapor-tight-high-bay-battery-backup

LED Parking Garage Emergency Lights With Battery Backup

UL924 | Vapor-Tight |  150 LPW 

Linear LED parking garage emergency lights battery backup are designed to replace fluorescent lights in the interior and exterior locations.  Such as warehouses, airports, tunnels, parking garages, and so on. In addition, these fixtures are built with a UL924 & CE-certified battery for backup lighting. This way they can get people out of the building in case of power outages, blackouts, fires, etc.

  • Emergency Backup: 90-180 minutes duration.
  • UL 924 & NFPA 101 Compliant
  • High Efficacy of up to 150 lumens per watt.
  • 5VA Rated 
  • Uniform illumination – Clear or frosted polycarbonate cover
  • 5-year Warranty 
  • Listings: DLC Premium, ETL/cETL Wet Location, CE/RoHS,  IP65 rated

Datasheet
Inquiry To Us

Features & Benefits

Intelligent Automatic Detection System

  • Built-in an emergency battery with min. 90 min. duration.
  • Meets with standard CSA C22.2 NO. 141 and UL924. 
  • Intelligent emergency automatic detection function to achieve emergency mode.
Lightide-BATTERY-BACKUP-of-emergency-led-garage-lights-1
Lightide NFPA 101 Compliant LED Lights

NFPA 101 Compliant

Each battery backup high bay light fixture provides at least 90 min. of illumination, with an average of 1-footcandle and a minimum of 0.1-footcandle when installed according to guidelines.

High Efficacy 150 LPW

With the high-performance SMD LEDs, emergency backup led high bay light outputs up to 150 lumens per watt, and are designed to replace less-efficient fluorescent strip lights.  In short, LED linear high bay lights are widely used for interior and exterior wet locations, such as car wash operations, airports, tunnels, maintenance areas, parking garages, and stairwells.

Lightide high efficacy 150 LPW of Vapor tight linear led high bay lights

Order Information | LED Garage Emergency Lights With Battery Backup

 Sample:  LT-TPA456-50K-EM-PC-F

LT- TP -A -4 -56 -50K -EM -3H -C
                Cover Option: Blank=Frosty, C=Clear
Emergency Time: Std.=90 minutes, 2H=120 minutes, 3H=180 minutes
Accessory: MS=Motion Sensor, PC=Photocell, EM=Emergency Kit
CCT: 30K=3000K, 40K=4000K, 50K=5000K, 57K=5700K
Power  code: 20=20w, 36=40w, 10=100w
Length  Code: 2=2′, 4=4′,  8=8′
 Code: A, B, C
Desc: Vapor Tight rated led high bay light

 

Specification | LED Garage Emergency Lights With Battery Backup

Model# Rating Power Lumen Output Equivalent RunTime (*) Voltage  Length  
LT-TPA220-EM 20W 2600 lm (Clear) 2x16w CFL 90~180 minutes 100-277vac 2′ REVIEW
LT-TPA436-EM 40W 5700 lm (clear) 2X36W CFL 4′ REVIEW
LT-TPA436-CP(T)-EM 32-40-50W Selectable 5700 lm @40W 2X56W CFL 4′  
LT-TPA810-EM 100W  15000 lm (clear)  4X56W CFL 8′ REVIEW

 

Compliant Standards | LED Garage Emergency Lights With Battery Backup

Certificate DLC Premium, ETL/cETL Wet Location
EMC/FCC/IC Standard EN55015, EN61547, EN61000-3-2/3, FCC part 15, ICES-005
Safety Stanard

UL1598, CAN/CSA -C.22.2 NO. 250.0, EN61347-1, EN61347-2-13, EN60598-2-1, EN60598-1,

UL924, NFPA 101 Compliant

NO. Description Document Version Date
1 Lightide Emergency Backup Vapor-tight led high bay lights datasheet
Download
A1 2022-01
2 Lightide Emergency Backup Vapor-tight led high bay lights sales sheet
Download
A 2018-08

    We will answer your email shortly!