Project Description
LED Parking Garage Emergency Lights With Battery Backup
UL924 | Vapor-Tight | 150 LPW
Linear LED parking garage emergency lights battery backup are designed to replace fluorescent lights in the interior and exterior locations. Such as warehouses, airports, tunnels, parking garages, and so on. In addition, these fixtures are built with a UL924 & CE-certified battery for backup lighting. This way they can get people out of the building in case of power outages, blackouts, fires, etc.
- Emergency Backup: 90-180 minutes duration.
- UL 924 & NFPA 101 Compliant
- High Efficacy of up to 150 lumens per watt.
- 5VA Rated
- Uniform illumination – Clear or frosted polycarbonate cover
- 5-year Warranty
- Listings: DLC Premium, ETL/cETL Wet Location, CE/RoHS, IP65 rated
Features & Benefits
Intelligent Automatic Detection System
- Built-in an emergency battery with min. 90 min. duration.
- Meets with standard CSA C22.2 NO. 141 and UL924.
- Intelligent emergency automatic detection function to achieve emergency mode.


NFPA 101 Compliant
Each battery backup high bay light fixture provides at least 90 min. of illumination, with an average of 1-footcandle and a minimum of 0.1-footcandle when installed according to guidelines.
High Efficacy 150 LPW
With the high-performance SMD LEDs, emergency backup led high bay light outputs up to 150 lumens per watt, and are designed to replace less-efficient fluorescent strip lights. In short, LED linear high bay lights are widely used for interior and exterior wet locations, such as car wash operations, airports, tunnels, maintenance areas, parking garages, and stairwells.

Order Information | LED Garage Emergency Lights With Battery Backup
Sample: LT-TPA456-50K-EM-PC-F
LT- | TP | -A | -4 | -56 | -50K | -EM | -3H | -C |
Cover Option: Blank=Frosty, C=Clear | ||||||||
Emergency Time: Std.=90 minutes, 2H=120 minutes, 3H=180 minutes | ||||||||
Accessory: MS=Motion Sensor, PC=Photocell, EM=Emergency Kit |
||||||||
CCT: 30K=3000K, 40K=4000K, 50K=5000K, 57K=5700K | ||||||||
Power code: 20=20w, 36=40w, 10=100w | ||||||||
Length Code: 2=2′, 4=4′, 8=8′ | ||||||||
Code: A, B, C | ||||||||
Desc: Vapor Tight rated led high bay light |
Specification | LED Garage Emergency Lights With Battery Backup
Model# | Rating Power | Lumen Output | Equivalent | RunTime (*) | Voltage | Length | |
LT-TPA220-EM | 20W | 2600 lm (Clear) | 2x16w CFL | 90~180 minutes | 100-277vac | 2′ | ![]() |
LT-TPA436-EM | 40W | 5700 lm (clear) | 2X36W CFL | 4′ | ![]() |
||
LT-TPA436-CP(T)-EM | 32-40-50W Selectable | 5700 lm @40W | 2X56W CFL | 4′ | |||
LT-TPA810-EM | 100W | 15000 lm (clear) | 4X56W CFL | 8′ | ![]() |
Compliant Standards | LED Garage Emergency Lights With Battery Backup
Certificate | DLC Premium, ETL/cETL Wet Location |
EMC/FCC/IC Standard | EN55015, EN61547, EN61000-3-2/3, FCC part 15, ICES-005 |
Safety Stanard |
UL1598, CAN/CSA -C.22.2 NO. 250.0, EN61347-1, EN61347-2-13, EN60598-2-1, EN60598-1, UL924, NFPA 101 Compliant |
NO. | Description | Document | Version | Date |
1 | Lightide Emergency Backup Vapor-tight led high bay lights datasheet | A1 | 2022-01 | |
2 | Lightide Emergency Backup Vapor-tight led high bay lights sales sheet | A | 2018-08 |